HUNTER-PRO 32 Intruder Alarm System - Installation Manual
58
NOTE:
To navigate on bar, use and keys.
Marking a “+” under a parameter’s letter enables the zone with this
parameter. Marking a “-” denies this possibility.
In order to change the mark from “-“ to “+” (and vise versa) use
Par. Para. Full Name Enabling this parameter means…
B
Bypassed
Permanently
(+) Permanently bypass a zone
0
Normally Open (+) Connect NO detector to a zone
F
24 Hour Zone (+) Zone active 24 hours
H
Active in Home 1 (+) Zone active in Home 1
H
Active in Home 2 (+) Zone active in Home 2
I
Entry Delayed (+) When system is armed this zone does not
activate alarm immediately (only after Entry Delay
time)
Possible to program two different sets of Entry
Delay time.
D
Zone Follower (+) When system is Armed and this zone is
activated after Entry Delayed zone, it does not
activate alarm immediately (only after Entry Delay
time). .
T
Second Delay
Time
(+) In order to choose the second “Delay Time”
E
EOL Resistors (+) Zone protected by EOL resistor/s. For
determining if system uses one EOL or two, refer
to “General Parameters” in section 5.6.