HUNTER-PRO 32 Intruder Alarm System - Installation Manual
60
SRKOA123HTBL
+---_++++---
Drawing 23-Zone
Responses screen
In this screen the three basic zone responses are
programmed: Alarm Panic and Smoke. All the
zones that get the same characteristics shall have
the same responses (refer to Zone Programming”
in section 5.3.1). In addition to these three, there
is also: Special Alarm 1, Special Alarm 2, Special
Alarm 3, Special Panic and Special Smoke.
S:
Siren
R:
Relay
K:
Smoke Output
O:
ON/OFF
A:
ALARM
1:
Expender 1 Output
2:
Expender 2 Output
3:
Expender 3 Output
H:
Private Dialer
T:
Different Siren Tone
B:
Automatic Bypass
L:
No Monitoring Station
during daytime (e.g. Fire
Exit)
5.3.4.1 Zone sensitivity
After programming the zone characteristics in each if the three basic groups
(Alarm, Panic and Smoke), you need to program the zones’ sensitivity by
multiplying the characteristics by 50msec (for example, to program 200msec
sensitivity, press 4).
In order to access this screen, press
after zone configuration is finished:
Sensitiv.(X50mS)
5.4 Communication Parameters
In this menu all the system’s communication functions are programmed: the
Monitoring Stations, Telephone Numbers, Report options, Formats, etc.