HUNTER-PRO 32 Intruder Alarm System - Installation Manual
62
Monitoring Station Protocol: In this screen the Monitoring Stations’
are programmed.
MS 1 Protocol
0 230
Monitoring Station Reports:
APFOLTWI
_+++++++ 1
In this screen the type of events reported to the Monitoring Station are
programmed:
A:
Alarms
P:
Panic
F:
Fire
O:
Open/Close
L:
Faults
T:
Tests
W:
Wake-up test
I:
Pressing technician code
5.4.1.4 Monitoring Station 2 Options
In this screen all features of Monitoring Station 2 are programmed.
All screens and programming procedures are similar to those in Monitoring
Station 1.
5.4.1.5 Partition Account Numbers
Account No.1
Pho:0 Rad:0
In this screen the Partitions’ Account Numbers (1-16) for telephone (Pho.) and
RF Transmitter (Radio) reports are programmed.
IMPORTANT!
In case Splits and Partitions are programmed in the system, their Account
Numbers need be programmed as well.
If an Account Number is not programmed, there will be no report for its
Partition/Split.
In a system with no Partitions/Splits, all settings will be registered under
“Partition 1”.