5.4.1.6 General Monitoring Station Options
In these screens the Communication’s different features are programmed:
Test Time and Interval:
Test Time:00:00
Interval:24 Hrs
Test Time
: The automatic test time is programmed in 24 hour format
(HH:MM). Note that the test time is similar to that of the PSTN
communication and radio backup to monitoring station.
Interval : The time between communications with the Monitoring
Station is programmed. The test is done by wired line (telephone) and
wireless line (Radio or GSM, depending on which is installed.)
Wait Time: In this screen you program the waiting time (in seconds)
until getting a confirmation sound from the Monitoring Station.
Ack Wait time
20 Seconds
5.4.1.7 Report Codes 4x2
These screens enable to program the different events’ Report Codes in 4x2
format (including all American formats.)
Each of the code’s digits can receive the value “0” to “15”. Values “10” to “15”
are represented by the letters “A” to “F” respectively, thus:
A=10
B=11
C=12
D=13
E=14
F=15
Changing a Report Code:
Enter the event you want to change
Place the cursor on the event’s digit using
and keys
Press the keypad keys in order to choose a digit from “0” to “9”