HUNTER-PRO 32 Intruder Alarm System - Installation Manual
64
Press the key as many times as needed in order to choose a
letter between “A” and “F”
Event Table in 4 x 2 Format
Z1 ,Z2 , ... Z32
Alarms according to zones.
R1 ,R2 , ... R32
RESET Code according to zones- reported after Siren Time.
When the system is programmed for reset according to
zone, the code will be reported only if the zone was closed.
ZFL
Faults according to EOL zones
BYP
Bypass Zones
R1 ,R2 , ... R32
RESET Code according to zones- reported after Siren Time.
When the system is programmed for reset according to
zone, the code will be reported only if the zone was closed.
TM1 ,ו- TM2
Open TAMPER 1 and/or TAMPER 2 and their Reset Codes
AC
Mains voltage failure (AC Fall) and Reset Code.
LB
Low Battery and Reset Code
PF
Card voltage lower than 9 volts (System Shutdown) and
Reset Code.
Low card voltage indicates AC Fall and Low Battery.
PHN
Telephone Line Fail and Reset Code.
FUS
Detector Voltage Fault and Reset Code.
TST
Test (manual, automatic, or “wake-up”).
PNC
Panic
ARM
Arming System
DISAR
Disarming System
FCODE
False Code
Note
In the display, the Reset Code appears as “REST” to the event’s right.
In case of a Double Report it is impossible to send a different 4X2 report to
both Monitoring Stations. It is possible to send a 4X2 report to one Monitoring
Station, and send a PAF or Contact ID report to the other Monitoring Station.