HUNTER-PRO 32 Intruder Alarm System - Installation Manual
65
Different Double Report Options
MS Format 1 MS Format 2
Event Report to MS 1
Event Report to MS 2
PIMA PIMA Default Default
American PIMA Programming* Default
American American Programming Programming
Contact ID Contact ID Default Default
American Contact ID Programming Default
PIMA Contact ID Default Default
Contact ID PIMA Default Default
*Programming: According to the installer’s programming.
5.4.2 Radio Transmitter
In this screen the radio transmitter protocols are configured.
5.4.2.1 Radio Protocol
Protocol: 0
No. of Trans:5
In this screen the Radio Protocol Code is programmed. The code can be
retrieved from PIMA’s Technical Support department.
5.4.2.2 Number of transmissions
The number of transmissions for each event sent to the monitoring station. The
number can range from 1 to 32.
5.4.2.3 Periodicity Test
In this screen you program the time between radio communication tests to the
monitoring station (hours and minutes).
Periodicity Test
Hrs:24 Min.s:0