HUNTER-PRO 32 Intruder Alarm System - Installation Manual
70
5.5.3 AC Report Delay
4
ENTR
ENTR
NEXT
X2
Timers, Counters
ENTER/NEXT/END
AC Report Delay
ENTER/NEXT/END
AC Report Delay
240 Minutes
ENTR
>Enter no. of minutes>
9
In this screen you program the time the system waits until reporting mains
failure (in minutes). Once the system identifies the mains is back, the timer
resets.
5.5.4 Soak Test Days
4
ENTR
ENTR
NEXT
X3
ENTR
Timers, Counters
ENTER/NEXT/END
>Enter no. of days>
Soak Test Days
ENTER/NEXT/END
Soak Test Days
3 Days
9
In this screen you program the number of days a zone will be tested. During
this period of time, any events initiated by the zone will not be reported to MS
nor trigger the alarm/private dialer, etc. These events will only be recorded in
the memory log. After this period of time, the zone will return to normal
operation.
Thus note that a zone in Test Days is different than bypassed zone.
NOTES:
The zone’s soak test can last up to 3 days.
In PIMA display: Alarms triggered by a Test Zone in the memory log have
the letter “T” under/above their number.
5.5.5 Double Knock
4
ENTR NEXT
X4
ENTR>Enter no. of seconds>
Timers, Counters
ENTER/NEXT/END
Double Knock
ENTER/NEXT/END
Double Knock
30 Seconds
9
ENTR
In this screen you program the range of time to verify alarm from a zone (in
seconds).