HUNTER-PRO 32 Intruder Alarm System - Installation Manual
80
5.11.4 Configuring Soak Test Zones
0
ENTR
ENTR
NEXT
Tests
ENTER/NEXT/END
Set Soak Zone
ENTER/NEXT/END
X3
Zone Number: 1
Entr-Conf #-Rst
9
When a detector is suspected of causing false alarms, it can be put to the test
in this screen. All events from a test zone will not trigger the alarm. If for a
defined term of time the test zone does not indicate an alarm event, the zone
will return to operate normally.
5.11.5 Siren Test
0
ENTR ENTR
NEXT
X4
Tests
ENTER/NEXT/END
Siren Test
ENTER/NEXT/END
9
Pressing will activate the siren
Press
to cancel the test
5.11.5 Monitoring Station Dialer Test
0
ENTR ENTR
NEXT
X5
Tests
ENTER/NEXT/END
Test MS Dialer
Select T.No. 1-4
9
This test is for checking the central monitoring station’s dialer. Pressing
will send a test report to the monitoring station for telephone number 1.
Pressing
will do so for telephone number 2, and so on.
5.11.6 Central Monitoring Station Radio Test
0
ENTR ENTR
NEXT
X6
Tests
ENTER/NEXT/END
Test MS Radio
ENTER/NEXT/END
9
This test is checking the wireless transmitter. Pressing will cause the
system to send a transmission test to monitoring station.