HUNTER-PRO 32 Intruder Alarm System - Installation Manual
87
7.3.4 AC Line
AC mains power failure. If other electrical appliances are working, then check
the entire AC conduit to the system.
Solution:
Connect AC power.
If you find a blown AC fuse, then replace the fuse; if failure persists
then replace the PCB.
7.3.5 Tamper
TAMPER 1: Tamper 1 is open.
TAMPER 2: Tamper 2 is open.
7.3.6 Zone
This failure can only appear in zones programmed as EOL protected, indicating
a short/disconnection of zone/s.
The LCD display will show the zone with the failure by marking a sign close to
the zone’s number.
7.3.7 Keyboard Not Connected
This is an indication that there is no data transfer between the control panel
and the keypad. Check the following:
Proper connection between the “OUT” terminal on the control panel
and the input to the keypad via the yellow wire.
Keypad receives 13.8V power supply. If the power source is not high
enough then check that there are not to many keypads connected to
the system (8 keypads max).
During RAM Test a message might appear. This is not a failure.
The Jumpers at the back of the keypad correspond to system
programming or partitioning.
Check for malfunction in the keypad – Replace Keypad.