HUNTER-PRO 32 Intruder Alarm System - Installation Manual
88
Check for malfunction in the control panel – Replace PBC.
NOTE:
If there are several keypads connected to the control panel and all show the
same indication then either the control panel PCB is malfunctioning or there is a
short on one of the wires
.
7.3.8 Telephone
The system did not recognize a dial tone. Appears after lack of communication
on the last dialing trial.
The failure indication will remain while the system is disarmed even though the
line and/or tone return.
To eliminate the ongoing display of this failure; run the TEST procedure by
pressing and holding the
key until the test procedure begins. The system
will perform a self–test that includes an update of telephone status.
NOTE:
Assure that no telephones or other equipment connected to the telephone are
active during the system dialing.
7.3.9 Communication
7.3.9.1 No telephone communication to MS during test mode
This indication appears if the HUNTER-PRO communicator cannot transfer
reports to MS. Possible reasons for this indication is incompatible protocols with
the Monitoring Station or phone failure.
Check the following:
The telephone line is properly connected to the LINE terminal blocks.
In Communication menu (section. 5.4) the “P” for telephone is
programmed with +.
At least one telephone number is programmed for MS.
Telephone account ID for MS is other than 0.
Format is compatible with the one used in the MS.