HUNTER-PRO 32 Intruder Alarm System - Installation Manual
89
Correct telephone numbers have been entered.
A prefix has been programmed if the system is installed in an office
(usually 9).
7.3.9.2 Checking communications to the Monitoring Station:
Enter Installer code without the Master Code, press and in order to
initiate an event and watch the progression of communication to the MS.
7.3.9.3 No Wireless Communication to CMS
Check the following:
Proper connection between the control panel and the transmitter.
Radio account ID is other than 0.
Station radio ID corresponds to the Monitoring Station.
Format is compatible with the one used in the Monitoring Station.
If the antenna is not installed on the HUNTER-PRO metal case, check
the extension cable for the antenna is intact.
Backup battery is connected and intact.
7.3.9.4 No Communication to Private Dialer
Check the following:
The telephone line is properly connected to IN terminal block inputs.
In Communication menu the “P” for telephone is programmed with +.
In zone responses + is programmed under subscriber dialer.
At least one telephone number is programmed for private numbers.
Correct telephone numbers have been entered.
A prefix has been programmed if the system is installed in an office
(usually 9).
7.3.9.5 System not answering Telephone Calls