28 HUNTER-PRO Series Installation Guide
LED Description Status
Flashes Signal has been acquired
VALID
(Green)
Acquiring a signal
from wireless devices
OFF Signal has not been acquired (no
reception from the wireless device)
One No valid frame is received from the panel
2 long
flashes
No ACK is received from the panel
3 long
flashes
The card is not programmed
FAIL
(Red)
Communication failure
with the control panel
4 long
flashes
General/Fatal error. Occurs when
no communication is received for one
minute
3.3 Connecting a Key
Connect a key or Key fob according to the next diagrams. The key can be set as
momentary or ON/OFF switch. The default is momentary.
Figure 24. Connecting a key
3.4 TMPR1, TMPR2: Tamper Switches
In addition to cases and boxes protection, the tampers can be used for panic buttons,
sensors (temperature, pressure etc.) with dry contact outputs and more.
Connect the tamper switch between the TMPR1/TMPR2 connections and ground (–).
TMPR1 input is connected to the tamper switch onboard the PCB.
A 10kΩ resistor at the terminal input on the PCB provides a short/disconnect indication,
since the tamper switches are NC type.
1. By default, TMPR1 & TMPR2 inputs are enabled and without EOL
(see section 5.7.1).
2. To use tamper #2 as zone #9, see section 5.7.1