HUNTER-PRO Series Installation Guide 69
5.6.9 Bypass Limit Time
Set the time (in minutes) in which a zone can be bypassed (by a user, during arming),
before it is automatically becomes armed again. This protects against burglary
preparation by bypassing zones before the system is armed.
5.6.10 False Code
Set the number of allowed keystrokes (max 24), after which the system reports the MS
and responds according to the system responses (see “System Responses” , section 5.8).
5.6.11 Inactivity Report
This feature serves as an indication if the system has not been armed (fully or partially)
for the number of days set in this screen. If so, a report is sent to the MS which can
then check the integrity of the system with the customer.
5.7 Key #5: General Parameters
ENTR
5
Gen. Parameters
ENTER/NEXT/END
General parameters are displayed in 2 consecutive screens.
5.7.1 First Screen
KD1E2EKAB2SMPZTF
--+-+--------+++
Par. Name Marking “+” means…
K State Key Switch (+) Toggle key (On/Off)
(-) Momentary key
D DC Siren DC Siren is installed
1 TAMPER 1 Connec. TMPR #1 output is active
E TAMPER 1 - EOL TMPR #1 output is protected by EOL circuit
2 TAMPER 2 Connec. (+) TMPR #2 output is active
(-) TMPR #2 output serves as zone #9
E TAMPER 2 - EOL TMPR #2 is protected by EOL circuit
K Key-> Home State Arming with a key arms to ‘HOME 1’
A Automatic-> HOME Automatic arming arms to ‘HOME 1’
B Byps. Zone in Au. Any opened zones are bypassed in auto-arming
2 2 EOL Resistors All EOL zones are protected by 2 resistors
S Siren beep in ARM The siren beeps once when arming the system.
When disarming with a key or remote control the
siren beeps twice.
M User Code-> Menu (+) Entering User code displays the user menu
(-) Entering User code arms/disarms the system
P Advanced Menu Enhanced communication menu is enabled