HUNTER-PRO Series Installation Guide 71
The differentiation of responses between armed & disarmed
modes, as in other PIMA systems like the HUNTER-PRO 32, does
not apply to HUNTER-PRO series and has been replaced by the
parameter ‘L’. See the next table
Par. Response Mark “+” means…
S Activate Siren 1. When the system is armed, both the internal and external
sirens are set off in alarm
2. When the system is disarmed, only the internal siren is set
off in alarm
S Ext. SRN in OFF The external siren is activated in alarm even when the system is
disarmed
A Act. Burgl Output Activate the burglary output type
L No Daytime MS The system does not report the MS when it is disarmed
5.9 Key #7: Outputs Configuration
7
ENT R
ENTR
Output Configur.
ENTER/NEXT/END
External Siren
ENTER/NEXT/END
ENT R
Part. for OUT
++++++++++++++++
PD
-+
ENTR
Output Type
Outputs partitions
Outp uts Polari ty
External Siren
External Siren
PCB’s (physical) output
Configure the PCB outputs and the output types (see section 1.7 to distinct between
the two). The outputs can be triggered based on partitions, i.e. be triggered only by
alarms generated in the allocated partitions.
By default, the output types are allocated to the most likely PCB outputs, so the
‘External siren’ output type, for example, is the default type for the PCB ‘Ext. SIREN’
output. It is not advisable to change these unless specific installation requirements.
5.9.1 PCB & Expanders Outputs
There are seven outputs on the system’s PCB: Ext. & Int. SIRENS, SMOKE, RELAY,
ON/OFF, ALRM, Audio Ctrl. The expanders' outputs are also set in this menu.
7
ENTR
Output Configur.
ENTER/NEXT/END
External Siren
ENTER/NEXT/END