72 HUNTER-PRO Series Installation Guide
Press
[NEXT]
PCB/Expanders
Output
X1 Internal Siren
X2 RELAY
X3 SMOKE (reset detectors)
X4 ON/OFF
X5 ALARM
X6 Audio Control
X7 OUT-1000 Outputs
X8 I/O-R Outputs
X9 I/O-8N Outputs
5.9.2 Output Types
Following, is a table of the output types by their order in the menu. To clarify, the
process of programming is as follows:
Pick an output and press [ENTR]; Pick an output type and press [ENTR]; Set the
output partition/s and press [ENTR]; set the output polarity (see how further on) and
press [ENTR];
Output type What trips the PCB output?
External Siren Alarm from a zone programmed to trigger the external siren
output type
Internal Siren Alarm from a zone programmed to trigger the internal siren
output type
Burglary Alarm from ‘Burglary’ zone type
*
Anti-Mask Alarm from ‘Anti-Mask’ zone type
Special Burglary 1 Alarm from ‘Special Burglary 1’ zone type
Special Burglary 2 Alarm from ‘Special Burglary 2’ zone type
Burglary - All
Types
All alarms from ‘Burglary’, ‘Special Burglary 1’ and ‘Special
Burglary 2’ zone types
Fire Alarms from ‘Fire’ zone type
Special Fire Alarms from ‘Special Fire’ zone type
Panic Alarms from ‘Panic’ zone type, or keypad panic code [*]+[#]
Silent Panic Alarms from ‘Silent Panic’ zone type
Hold-Up (Duress) Alarms from ‘Hold-Up (Duress)’ zone type, or keypad hold-up
code
Medical Alarms from ‘Medical’ zone type
Alarms - All Types All the alarms from all the zones
Audio Control Activating audio (MIC-200) or voice unit (VU-20N)
Zone Open Zone violation
Zone Bypassed Zone bypassing
*
All the zone types are programmed by default to activate the external siren in
response to alarm. To change this, see section 0 5.8.