HUNTER-PRO Series Installation Guide 73
Output type What trips the PCB output?
Smoke Detector
Power
Resetting smoke detectors
Tamper Tamper switch opened
Zone Tamper/fail Zone tamper switch triggered or zone failure
Buzzer Keypad buzzer activated
Armed Arming the system
Installer Program Entering installer code
General Fault System general fault
MAINS Fault Mains fault
Low Battery Low battery fault
Phone Fault Phone fault
GSM Fault GSM fault
Communication
Fault
Failing to communicate with the MS
Not In Use -
Door Code Entering a door code
Wireless Remote
Pressing the [*] button in a remote control
Test Sending test report
Not In Use -
Not In Use -
Remote Control Activating an output remotely
Not Used -
Station ACK ACK received from the MS*.
* This output type is used for indication that a report that was previously sent to the
MS has been received. When an alarm from a zone programmed to set off the “Station
ACK” output type occurs, the PCB output programmed to be triggered by this output
type “waits” for the system to receive ACK. As soon as the ACK is received the output
is tripped for 10 seconds (and can turn on a bulb, for example).
5.9.3 Output Partitions
Set the outputs partitions (see drawing in section 5.9), i.e. define which partitions are
enabled to activate which output.
5.9.4 Polarity & Activation in Disarm
Set the polarity of the output and whether it will be activated when the system is
disarmed (See the drawing in section 5.9).
Par. Name When setting to “+”
P Polarity
<+=Pos.
‘+’: The output is normally tripped and is disconnected during alarms
‘-’: The output is switched to GND during alarms
D Active in
Disarm
‘+’: The output is tripped when the system is disarmed
‘-’: The output is tripped when the system is armed