74 HUNTER-PRO Series Installation Guide
5.9.5 ‘Ext. Siren’ and ‘Int. Siren’ Outputs
These 2 onboard outputs are both high current outputs and can trigger any speaker
siren. However, the ‘Ext. Siren’ output can be triggered only when the ‘Int. Siren’
output is. As a result, the sirens connected to the HUNTER-PRO series can be activated
in one of 3 ways: Both the internal and external, the internal only & no siren at all.
It is recommended not to allocate to the ‘Ext. Siren’ and ‘Int. Siren’
PCB outputs any other but the same output types
5.9.6 Expanders’ Outputs
5.9.6.1 OUT-1000
7
ENTR ENTRB ACK
ENTR
O utp ut C on fig ur .
E NTE R/N EX T/E ND
O UT -10 00 Out put s
E NT ER/ NEX T/ END
O utp ut 1
X3
O utp ut 1
F ire
ENTR
Part. For OUT 1
++ +++ ++ +++ +++ +++
PD
-+ 1
ENTR
Expan der
Expa nder’s output No.
O utput’s output type
Output’s partitions
Output’s polarity
Output’s No.
Configure the OUT-1000 (8 outputs expansion card) outputs. The screens are the same
as those of the PCB outputs.
Press [NEXT] to configure the I/O-R 8 relays expansion card and the I/O-8N and I/O-
16 outputs card
5.9.7 Examples for Programming the Outputs
1. ON/OFF output:
7
ENTR ENTR
NE XT
EN T R
Out put Co nfi gur .
ENT ER /NE XT/ END
O N/O FF O utp ut
E NTE R/N EXT /E ND
X4
Par t. F or O UT 1
+++ --- -++ --- +++
PD
-+
ENTR
Pick an output
Set output type
Enable partitions to
activate the output type
Set output’s polarity
& active in disarm
ON /O FF O utp ut
Ar med
The procedure is as follows: First, pick the ON/OFF output. Then, determine what
output type will be allocated (trigger) to it. In this case, the default output type is
‘Armed’, so when the system becomes armed, the ON/OFF output is tripped.
Then, determine from within which partition/s this output can be triggered. Then set
the polarity of the output.