86 HUNTER-PRO Series Installation Guide
Communication faults
W/L Unit Tamper Wireless receiver’s tamper is opened or out-of-order. Check that
its cover is closed
For further information on I/O-WN, refer to the I/O-WN guide
Check Keypad
number
Keypad’s ID does not match the programmed no. of keypads
MS. Com. Fault Failure to communicate with the MS including in test mode.
This fault appears if the HUNTER-PRO communicator cannot
transfer reports to MS. Possible reasons are incompatible protocol
or phone line failure.
Check the following:
The telephone line is properly connected to the LINE
terminal blocks.
In Communication menu (section. 5.4) the “P” for telephone
is programmed with “+”.
At least one MS telephone number is programmed.
Telephone account ID for MS is other than 0.
Comm. format is compatible with the one used in the MS.
Correct telephone numbers have been entered.
If the system is connected to an extension of a private
switchboard a prefix has been programmed.
SMS Com. Failure Communication failure between the system and the provider’s
SMS center
Install SMS Unit SMS-100 unit is not installed
Network Fault Communication failure between the system and the PIMAnet card.
IO-R X Fault Fault in I/O-R relay expander
IO-R X Tamper I/O-R tamper is open
IO-R X Voltage Low voltage to I/O-R
Wireless Jamming Radio channel is jammed
IO-8 X Voltage Low voltage to I/O-8
Supervision: Wireless detector ceased to send reports to the system
System Error The EPROM version and the system’s software version do not
match. Contact PIMA support
If more than one fault occurs simultaneously they will be displayed
one by one