Why is my Pioneer Air Systems Dehumidifier refrigerant compressor cycling due to high refrigerant pressure or overload?
- SSavannah FranklinAug 12, 2025
The refrigerant compressor might be cycling due to several reasons: the unit is overloaded, the surrounding atmosphere is dirty, the ambient temperature is too high, the condenser fan motor has failed, the high-pressure shutdown setting is incorrect, or the compressor is faulty. To address this, you can reduce the load or install a larger system, clean the condenser and install a filter, relocate the unit or convert to a water-cooled unit, provide suitable ventilation or relocate the unit, consult the factory, or repair or replace the compressor. If you are going to replace the compressor, replace liquid and suction line filters.