Function Code Tables PE6000 User Manual
56
Function
Code
Parameter Name Setting Range Default Property
P5-06
FMP function
selection
0: Running frequency
1:Set frequency
2:Output current
3: Output torque (absolute value)
4: Output power
5:Output voltage
6:Pulse input
(100% corresponds 100.0kHz)
7: AI1
8: AI2
11: Count value
12: Communication setting
13: Motor rotational speed
14: Output current
(100% corresponds 1000.0A)
15: Output voltage
(100% corresponds 1000.0V)
16: Reserved
0
P5-07
AO2 function
selection
0
P5-09
Maximum FMP
output frequency
0.01–100.00 kHz 50.00kHz
P5-10
AO1 offset
coefficient
-100.0%–100.0% 0.0%
P5-11
AO1 gain -10.00–10.00 1.00
P5-17
FMR output delay
time
0.0–3600.0s 0.0s
P5-18
Relay 1 output
close delay time
0.0–3600.0s 0.0s
P5-19
Relay 1 output
open delay time
0.0–3600.0s 0.0s
P5-20
DO1 output delay
time
0.0–3600.0s 0.0s
Group P6: Start/Stop Control
P6-00
Start mode
0: Direct start
1: Rotational speed tracking restart
2: Pre-excited start (asynchronous
motor)
0
P6-01
Rotational speed
tracking mode
0: From frequency at stop
1: From zero speed
2: From maximum frequency
0
P6-02
Rotational speed
tracking speed
1-100 20
P6-03
Startup frequency 0.00 to P0-P8 0.00 Hz
P6-04
Startup frequency
holding time
0.0 to 100.0s 0.0s

Table of Contents