- 32 -
GB
Parameter Description Default min MAX
P23 Polarity for safety device alarm 0 0 1
0: DI Open = HP Alarm active
1: DI closed = HP Alarm active
P24
P25 Duration of Sterilization process 15 min 0 min 90 min
P26 Minimum temperature for sterilization start +15°C 0°C 100°C
P27 Min. temperature for the core probe heating start -5°C -50°C +50°C
P28 Duration of the core probe heating 90 sec 0 sec 600 sec
P29 Final temperature of core probe heating +30°C 0°C 100°C
P30 Differential for ON-OFF compressor +1°C 0°C 20°C
P31 Min.time between OFF-ON compressor 2 min 0 min 30 min
P32
Offset for core probe with faulty cold room probe and core probe not inserted
-2°C -10°C 10°C
P33 Min. core probe temperature for chilling/freezing start +70°C 0°C 90°C
P34 Duration of core probe insertion test (0=text excluded) 5 min 0 min 240 min
P35 Fan ON with compressor OFF in conservation phase 30 sec 0 sec 999 sec
P36 Fan OFF with compressor OFF in conservation phase 300 sec 0 sec 999 sec
P37 Core temperature difference during core probe insertion test +4°C 0 +10°C
P38 Temperature difference between core and cold room during +5°C 0 +10°C
core probe insertion test
P39
P40 Unit address for external haccp monitoring system 1 1 147
P41 Serial connection: 0 = not used 1 0 2
1 = Printer
2 = ModBus
P42 BaudRate: 0= 2400; 1 = 4800; 2 = 9600; 2 0 2
P43 Parity : 0= no parity; 1= odd; 2 = even 2 0 2
P44 Time interval between 2 following prints 10 min 1 min 60 min
P50 Carrying out defrosting at chilling/freezing cycle: 0 0 1
0=No;1=Yes
P51 Final temperature at the end of the defrosting process +8°C -10°C +30°C
P52 Max. duration of the defrosting process 15 min 1 min 90 min
P53
Time interval between 2 following defrosting process in conservation phase:
0=excluded 0 hours 0 18 hours
P54 Defrosting type: 0 0 2
0= wit hair circulation 1= hot-gas 2= electric
P55 Dripping time after defrosting process 1 min 0 min 90 min
P56 Delay for compressor activation with hot-gas defrosting 0 sec 0 sec 600 sec
P57 Minimum temperature for defrosting process activation +3°C -10°C +30°C
P58 Temperature differential for fan stop after defrosting +5°C 0°C +10°C
P60 Compressor ON in chilling cycle with faulty cold room probe and core probe inserted 3 min 0 min 60 min
P61 Compressor OFF in chilling cycle with faulty cold room probe and core probe inserted 7 min 0 min 60 min
P62 Compressor ON in freezing cycle with faulty cold room probe and core probe inserted 8 min 0 min 60 min
P63 Compressor OFF in freezing cycle with faulty cold room probe and core probe inserted 2 min 0 min 60 min
P65 Delay for compressor start-up after swichting on electronic board 2 min 0 min 60 min