3.8 Insulation
Choose the installation site considering the high
temperatures (up to 500 °С, depending on capacity) during
installation of the exhaust pipe.Install thermal insulation
over the exhaust pipe to protect vehicle equipment
(electrical wiring and other lines) from high temperatures
(Fig. 14).3.9 Fuel Supply.
Do not operate the heater using biofuel.
3.9.1 Fuel Tank Installation
Installation of the fuel tank is shown in Fig.23.
Install the fuel tank in a way so that fuel that
may leak during the tank filling will not be
spilled onto the exhaust system and electric
wiring.
Fuel filler shall not be situated in the
passenger compartment, trunk, or engine
compartment.
If the fuel tank is positioned on vehicle side, it and its
installed plug must not protrude beyond outer dimensions
of the vehicle.
In order to avoid leakage of fuel from the fuel tank (by
gravity) when the fuel pump loses its tightness, the fuel tank
should be preferably placed in such a way that the maximum
fuel level is below the cut-off plane of the fuel tube of the heater.