16
• 00 = Built in Air Sensor
• 01 = Remote Air Sensor
• 02 = Floor Sensor Only
• 03 = Floor Sensors & Built in Air Sensor
• 04 = Floor Sensor and Remote Air Sensor
Feature 09 – Floor Limit: When the thermostat is operating
in mode 01 and 03 (as described on page 13) and function 08
is set to 02, 03 or 04, function 09 becomes available. You can
default).
Feature 10 – Optimum Start: Optimum start will delay the
start up of the heating system to the latest possible moment to
avoid unnecessary heating, so that the dwelling is comfortably
warm by the programmed time. The thermostat uses the rate of
change (see below) setting to calculate how long the building
needs to take to raise the building 1°C (with a rate of change
of 20, the thermostat has calculated the building needs 20
minutes to raise the building 1°C).
Feature 11 – Rate of Change: For information only.