11
1. Transport of equipment containing flammable
refrigerants
See transport regulations
2. Marking of equipment using signs
See local regulations
3. Disposal of equipment using flammable refrigerants
See national regulations.
4. Storage of equipment/appliances
The storage of equipment should be in accordance
with the manufacturer's instructions.
5. Storage of packed (unsold) equipment
Storage package protection should be constructed
such that mechanical damage to the equipment
inside the package will not cause a leak of the
refrigerant charge. The maximum number of pieces
of equipment permitted to be stored together will be
determined by local regulations.
6. Information on servicing
1) Checks to the area
Prior to beginning work on systems containing
flammable refrigerants, safety checks are necessary
to ensure that the risk of ignition is minimised. For
repair to the refrigerating system, the following
precautions shall be complied with prior to conducting
work on the system.
2) Work procedure
Work shall be undertaken under a controlled