7.36
9928487 R01 - 2018 RANGER XP 1000 Service Manual
© Copyright Polaris Industries Inc.
13.Install the RH output hub
e
into the gearcase
housing. The output hub should spin freely.
14.Install the cover plate assembly with a new o-ring
onto the gearcase.
NOTE
Verify the square O-ring is placed flat on the cover
surface. If the O-ring is twisted, fluid leaks may occur.
15.Torque the cover plate bolts
w
to specification.
TORQUE
AWD Cover Screws:
8 ft-lbs (11 Nm)
16.Fill the gearcase with fluid.
FLUID CAPACITY
Demand Drive
Hub Fluid
8.97 oz. (265 ml)
17.Install the drain plug. Torque to specification.
TORQUE
Fill / Drain Plug:
10 ft-lbs (14 Nm)
FINAL DRIVE