Indicates an immediate and specific hazard that will result in severe personal injury or death.
Read and understand all instructions before using the tool to reduce risk of personal injury and equipment damage.
Operate in a safe work environment, keep area clean, well-lit, free of distractions, and away from children.
Details on essential PPE like safety goggles, gloves, clothing, and footwear.
Measures to avoid injury by controlling the tool, personal movement, and work environment.
Strict adherence to tool safety rules is crucial, as familiarity can lead to serious injury.
Precautions regarding hydraulic fluid, including potential injection hazards and handling.
Immediate medical attention is critical if hydraulic fluid penetrates skin due to toxic reaction risk.
Follow precautions to avoid injection injury from high-pressure fluid, including wearing PPE and checking for leaks.
Guidelines for safe operation, including grounding, avoiding wet conditions, and proper cord handling.
Precautions for operating the power tool safely, including avoiding malfunctioning controls and ensuring proper cooling.
Tool uses a 120V, single-phase three-prong grounded power supply cord and plug.
Guidelines for using extension cords, including rating, gauge, length, and GFCI usage for safe operation.
Instructions for unpacking the tool, inspecting for damage, and ensuring all parts are included.
Step-by-step instructions for assembling the log splitter, including fitting support legs and securing bolts.
How to adjust the ram length and install the stroke limiter for shorter logs.
Step-by-step guide on how to split logs, including log placement, stroke adjustment, and wedge usage.
Safe procedure to remove a jammed log without splitting it, using a split log wedge.
Maintain the tool with care for efficiency and fewer problems. Keep it clean, dry, and free from oil/grease.
Monthly maintenance for the hydraulic ram, including lubrication, inspection, and proper storage.
Solutions for logs not splitting, including log positioning, size, wedge condition, and oil leaks.
Solutions for a jerky log pusher, including checking hydraulic oil level and air in the system.
Solutions for oil leaks, including tightening bleed screw, drain bolt, and checking valve assembly.
Schematic of the log splitter's wiring system for reference.
Schematic of the log splitter's hydraulic system for reference.