Chapter 5 Function parameter
34
Chapter 5
1
199
F7.37
Random arrivals current
1 width
0.0% to 300.0% (Rated motor
current)
0.0%
200
F7.38
Random arrivals current
2
0.0% to 300.0% (Rated motor
current)
100%
201
F7.39
Random arrivals current
2 width
0.0% to 300.0% (Rated motor
current)
0.0%
202
F7.40
Module temperature
arrival
0 to 100
75
203
F7.41
Cooling fan control
0: Fan running only when running
1: Fan always running
0
204
F7.42
Timing function selection
0: Invalid 1: Valid
0
205
F7.43
Timing run time
selection
0: F7.44 setting
1: AI1
2: Reserve
3: Panel potentiometer
0
206
F7.44
Timing run time
0.0Min to 6500.0Min
0.0Min
207
F7.45
Current running reaches
the set time.
0.0Min to 6500.0Min
0.0Min
208
F7.46
Awakens frequency
dormancy frequency(F7.48)to
maximum frequency (F0.19)
0.00Hz
209
F7.47
Awakens delay time
0.0s to 6500.0s
0.0s
210
F7.48
Dormancy frequency
0.00Hz to awakens frequency(F7.46)
0.00Hz
211
F7.49
Dormancy delay time
0.0s to 6500.0s
0.0s
212
F7.50
AI1 input voltage
protection lower limit
0.00V to F7.51
3.1V
213
F7.51
AI1 input voltage
protection upper limit
F7.50 to 10.00V
6.8V
5-1-10.F8 Group - Fault and protection
No.
Code
Parameter name
Setting range
Factory
setting
Cha
nge
214
F8.00
Overcurrent stall gain
0 to 100
20
215
F8.01
Overcurrent stall
protection current
100% to 200%
150%
216
F8.02
Motor overload
protection selection
0: Disable
1: Enable
1
217
F8.03
Motor overload
protection gain
0.20 to 10.00
1.00