Chapter 5 Function parameter
41
Chapter 5
316
E1.40
11 stage running time T11
0.0s(h) to 6500.0s(h)
0.0s(h)
317
E1.41
11 stage ac/deceleration time
selection
0 to 3
0
318
E1.42
12 stage running time T12
0.0s(h) to 6500.0s(h)
0.0s(h)
319
E1.43
12 stage ac/deceleration time
selection
0 to 3
0
320
E1.44
13 stage running time T13
0.0s(h) to 6500.0s(h)
0.0s(h)
321
E1.45
13 stage ac/deceleration time
selection
0 to 3
0
322
E1.46
14 stage running time T14
0.0s(h) to 6500.0s(h)
0.0s(h)
323
E1.47
14 stage ac/deceleration time
selection
0 to 3
0
324
E1.48
15 stage running time T15
0.0s(h) to 6500.0s(h)
0.0s(h)
325
E1.49
15 stage ac/deceleration time
selection
0 to 3
0
326
E1.50
Simple PLC run-time unit
0: s (Seconds) 1: H (hours)
0
327
E1.51
Multi-stage command 0
setting mode
0: Function code E1.00 reference
1: Analog AI1 reference
2: Analog AI2 reference
3: Panel potentiometer setting
4: High-speed pulse setting
5: PID control setting
6: Keyboard set frequency
(F0.01) setting, UP/DOWN can
be modified
0
5-1-17.E2 Group - PID function
No.
Code
Parameter name
Setting range
Factory
setting
Change
328
E2.00
PID setting source
0: E2.01 setting
1: Analog AI1 reference
2: Reserved
3: Panel potentiometer setting
4: High-speed pulse setting
5: Communications reference
6: Multi-stage command
reference
0
329
E2.01
PID keyboard setting
0.0% to 100.0%
50.0%
330
E2.02
PID feedback source
0 to 5
0
331
E2.03
PID action direction
0: Positive 1: Negative
0
332
E2.04
PID setting feedback range
0 to 65535
1000