Chapter 5 Function parameter
76
Chapter 5
number
0
1
1
1
1
0
1
0
0
1
0
0
1
1
1
1
To devide four data into a group , total four groups.
Position No.
15-12
11-8
7-4
3-0
Value
0111
1010
0100
1111
Then can check out the result 0x7A4F according to the below table ( binary/ hexadecimal
value table ).
Binary Hexadecimal
0000
0001
0010
0011
0100
0101
0110
0111
1000
1001
1010
1011
1100
1101
1110
1111
0
1
2
3
4
5
6
7
8
9
A
B
C
D
E
F
Binary
Binary
Binary
Hexadecimal
Hexadecimal
Hexadecimal
F6.02
Running status display
parameters
2
0x0000 0xFFFF
0000
0
1
2
3
4
5
6
7
8
910
11
1213
14
15
Present charge time(Min)
Line speed
Rest time of running
Running frequency2(Hz)
High speed pulse input
frequency(kHz)
PLC range
PID feedback
Present running time(Min)
High speed pulse input
frequency(Hz)
Communication parameters
encoder feedback speed(Hz)
Assistance frequency B
display(Hz)
Main frequency A display(Hz)
Ordering torque
Remain
Synchronous machine
wheel position
Figure 5-15:Running status display parameters 2
If the above parameters need to be displayed in operation, firstly set its position to 1, and
then set at F6.02 after converting the binary number to the hexadecimal number.
Running status display parameters, which is used to set the parameters that can be viewed
when the inverter is in operation.
There are 32 parameters available for viewing, select desired status parameters according
to F6.01, F6.02 binary parameter values, the display order starts from the lowest level of F
6.01.
F6.03
Stop status display parameters
0x00010xFFFF
0013
0
1
2
3
4
5
6
7
8
910
11
121314
15
DI input situation
Bus voltage
(V)
Setting frequency
DO output situation
AI1 voltage
(Hz)
Count value
Remain
Length
Load speed
PID setting
(V)
PLC range
High speed pulse
input frequency
(Hz)
Remain
Remain
Remain
Remain
Figure 5-16:Stop status display parameters
If the above parameters need to be displayed on operation, firstly set its position to 1, and
then set at F6.03 after converting the binary number to the
dexadecimal number. Please see the
detail of converting the binary number to the hexadecimal number.
F6.04
Load speed display coefficient
0.00016.5000
3.0000
When load speed needs to be displayed , adjust the inverters output frequency and load
speed by using the parameter.