Chapter 5 Function parameter
33
Chapter 5
than lower limit
frequency mode
1: Stop
2: Zero speed running
181
F7.19
Droop control
0.00Hz to 10.00Hz
0.00Hz
182
F7.20
Setting cumulative
power-on arrival time
0h to 36000h
0h
183
F7.21
Setting cumulative
running arrival time
0h to 36000h
0h
184
F7.22
Start protection
selection
0: OFF 1: ON
0
185
F7.23
Frequency detection
value (FDT1)
0.00Hz to F0.19(Maximum
frequency)
50.00Hz
186
F7.24
Frequency detection
hysteresis value (FDT1)
0.0% to 100.0% (FDT1 level)
5.0%
187
F7.25
Frequency reaches
detection width
0.00 to 100% (Maximum frequency)
0.0%
188
F7.26
Frequency detection
value (FDT2)
0.00Hz to F0.19 (Maximum
frequency)
50.00Hz
189
F7.27
Frequency detection
hysteresis value (FDT2)
0.0% to 100.0% (FDT2 level)
5.0%
190
F7.28
Random arrivals
frequency detection
value 1
0.00Hz to F0.19 (Maximum
frequency)
50.00Hz
191
F7.29
Random arrivals
frequency detection
width 1
0.00% to 100.0% (Maximum
frequency)
0.0%
192
F7.30
Random arrivals
frequency detection
value 2
0.00Hz to F0.19 (Maximum
frequency)
50.00Hz
193
F7.31
Random arrivals
frequency detection
width 2
0.00% to 100.0% (Maximum
frequency)
0.0%
194
F7.32
Zero current detection
level
0.0% to 300.0% (Rated motor
current)
5.0%
195
F7.33
Zero current detection
delay time
0.01s to 360.00s
0.10s
196
F7.34
Overrun value of output
current
0.0% (not detected)
0.1% to 300.0% (Rated motor
current)
200.0%
197
F7.35
Output current overrun
detection delay time
0.00s to 360.00s
0.00s
198
F7.36
Random arrivals current
0.0% to 300.0% (Rated motor current)
100%

Table of Contents