Chapter 5 Function parameter
38
Chapter 5
maximum frequency
frequency)
252
FA.07
Torque filter time
0.00s to 10.00s
0.00s
5-1-13.Fb Group - Control optimization parameters
No.
Code
Parameter name
Setting range
Factory
setting
Chan
ge
253
Fb.00
Fast current limiting manner
0: Disable 1: Enable
1
254
Fb.01
Undervoltage point setting
50.0% to 140.0%
100.0%
255
Fb.02
Overvoltage point setting
200.0V to 2500.0V
-
256
Fb.03
Deadband compensation mode
selection
0: No compensation
1: Compensation mode 1
2: Compensation mode 2
1
257
Fb.04
Current detection compensation
0 to 100
5
258
Fb.05
Vector optimization without PG
mode selection
0: No optimization
1: Optimization mode 1
2: Optimization mode 2
1
259
Fb.06
Upper limiting frequency for
DPWM switching
0.00Hz to 15.00Hz
12.00
Hz
260
Fb.07
PWM modulation manner
0: Asynchronous
1: Synchronou
0
261
Fb.08
Random PWM depth
0: Invalid
1 to 10: PWM carrier frequency
random depth
0
5-1-14.FC Group - Extended parameter group
No.
Code
Parameter name
Setting range
Factory
setting
Chan
ge
262
FC.01
Proportional linkage
coefficient
0.00 to 10.00
0
263
FC.02
PID start
deviation
0.0 to 100.0
0
5-1-15.E0 Group - Wobbulate, fixed-length and counting
No.
Code
Parameter name
Setting range
Factory
setting
Cha
nge
264
E0.00
Swing setting manner
0: Relative to center frequency
1: Relative to maximum frequency
0
265
E0.01
Wobbulate range
0.0% to 100.0%
0.0%
266
E0.02
Sudden jump frequency
range
0.0% to 50.0%
0.0%
267
E0.03
Wobbulate cycle
0.1s to 3000.0s
10.0s
268
E0.04
Triangle wave rise time
0.1% to 100.0%
50.0%

Table of Contents