Chapter 5 Function parameter
30
Chapter 5
29
d0.28
Auxiliary frequency
display
Frequency set by F0.04 auxiliary frequency
setting source
0.01Hz
30
d0.29
Command torque (%)
Observe the set command torque under the
torque control mode
0.1%
31
d0.30
Reserve
32
d0.31
Synchro rotor position
Synchro rotor position angle
0.0°
33
d0.32
Resolver position
Rotor position when rotary transformer is
used as a speed feedback
-
34
d0.33
ABZ position
Position information calculated from when
ABZ incremental feedback encoder is
adopted
0
35
d0.34
Z signal counter
Encoder Z-phase signal count
-
36
d0.35
Inverter status
Display run, standby and other statuses
-
37
d0.36
Inverter type
1.G type (constant torque load type)
2.F type (fans/pumps load type)
-
38
d0.37
AI1 voltage before
correction
Input voltage value before AI1 linear
correction
0.01V
39
d0.38
AI2 voltage before
correction
Input voltage value before AI2 linear
correction
0.01V
40
d0.39
AI3 voltage before
correction
Input voltage value before AI3 linear
correction
0.01V
41
d0.40
Reserve
42
d0.41
motor temperature
inspection function3
PT100 inspect motor temperature value
0
5-1-2.F0 Group -Basic function group
No.
Code
Parameter name
Setting range
Factory
setting
Chan-
ge
43
F0.00
Motor control manner
0.Vector control W/O PG
1.Vector control W/ PG
2.V/F control
2
44
F0.01
Keyboard set frequency
0.00Hz to F0.19 (maximum frequency)
50
.
00Hz
45
F0.02
Frequency command
resolution
1: 0.1Hz 2: 0.01Hz
2
46
F0.03
Frequency source master
setting
0: frequency setting by keyboard
(F0.01, UP/DOWN can be modified, no
memory when power off )
1. frequency setting by keyboard
(F0.01, UP/DOWN can be modified,
memory when power off )
2: analogquantity AI1 setting
3: analogquantity AI2 setting
4: panel potentiometer setting
5: high speed pulse setting
6: multi-speed running setting
7: simple PLC program setting
8: PID control setting
9: remote communication setting
1

Table of Contents