Chapter 5 Function parameter
32
Chapter 5
57
F0.14
Deceleration time 1
0.00s to 6500s
Depends
on models
58
F0.15
Ac/Deceleration time
unit
0:1 second1:0.1 second
2:0.01 second
1
59
F0.16
Ac/deceleration time
reference frequency
0: F0.19(maximum frequency)
1: Set frequency
2: 100Hz
0
60
F0.17
Carrier frequency
adjustment as per
temperature
0:
NO 1:
YES
0
61
F0.18
Carrier Frequency
0.5kHz to 16.0kHz
Depends
on
models
62
F0.19
Maximum output
frequency
50.00Hz to 320.00Hz
50.00Hz
63
F0.20
Upper limit frequency
source
0: F0.21 setting
1: AI1analog quantity setting
2: AI2 analog quantity setting
3: Panel encoder setting
4: High-speed pulse setting
5: communications reference
6:AI3 analog quantity setting
0
64
F0.21
Upper limit frequency
F0.23 (lower limit frequency) to
F0.19(maximum frequency)
50.00Hz
65
F0.22
Upper limit frequency
offset
0.00Hz to F0.19 (maximum frequency)
0.00Hz
66
F0.23
Lower limit frequency
0.00Hz to F0.21 (upper limit frequency)
0.00Hz
67
F0.24
Running direction
0:
same direction; 1: opposite direction
0
68
F0.25
Reserve
69
F0.26
AI Simulation accuracy
0: 0.01Hz 1: 0.05Hz
2: 0.1Hz 3: 0.5Hz
1
70
F0.27
GF type
1.G type (constant torque load type)
2.F type (fans/pumps load type)
-
5-1-3.F1 Group - Input terminals group
No.
Code
Parameter name
Setting range
Factory
setting
Chan-
ge
71
F1.00
DI1 terminal function selection
0 to 51
1
72
F1.01
DI2 terminal function selection
2
73
F1.02
DI3 terminal function selection
8
74
F1.03
DI4 terminal function selection
9
75
F1.04
DI5 terminal function selection
12
76
F1.05
DI6 terminal function selection
13
77
F1.06
DI7 terminal function selection
0
78
F1.07
DI8 terminal function selection
0
79
F1.08