Appendix V
104
Three-wire control mode 1
DI1 terminal function selection
DI2 terminal function selection
Three-wire operation control
DI3 terminal function selection
DI4 terminal function selection
DI5 terminal function selection
Terminal UP/DOWN change rate
Used to set terminal UP/DOWN
adjustment frequency, the rate of
frequency change.
V-9. External analog speed control (external 0 ~ 10V voltage
signal given)
V-9-1 electrical diagram:
Circuit breaker
380V 50/60Hz
Three phase input power supply
Motor
%
M
0~+10V DC
(Default)
FWD/STOP
REV/STOP
External simulation speed regulation
(External 0 ~ 10V voltage signal given)
0 ~ 10V Analog signal
V-9-2 Connection:
The (+) terminal of the external analog signal is connected to the AI1 terminal,
and the other terminal of the signal is connected to the GND terminal of the inverter.
V-9-3 Parameter setting:
Frequency source master setting
AI1analog quantity setting
Terminal block control (LED on)
DI1 terminal function selection
DI2 terminal function selection
V-10. External analog speed control (external 0 ~ 20mA
current signal given)