EasyManua.ls Logo

Powtran PI500-S 022G3 - Chapter 5 Function Parameter; Menu Grouping; D0 Group - Monitoring Function Group

Powtran PI500-S 022G3
82 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
24
Chapter 5
Chapter 5 Function parameter
5-1.Menu grouping
Note:
”: In running status, can not modify the parameter setting
“●”: The actual testing data, can not be modified
”: In stop and run statuses, both can be changed;
“▲”: “Factory parameter”, no change about it.
“_” means the factory parameter is related to power or model. Please check the details in the
involved parameter introduction.
Note:“Italic ³”means software version is C3.00 and the keyboard just like the above with
MCU can do the functions.
Change limit refers to whether the parameters are adjustable.
y0.01 is used for parameters protection password. Parameter menu can be enter into only after
inputting the right password in the function parameter mode or user change parameter mode. When
the y0.01 set to 0, the password is canceled.
Parameter menu is not protected by password under user customized parameters mode.
F group is the basic function parameters,E group is to enhance function parameters, b group is
a function of motor parameters,d group is the monitoring function parameters.
PI500-S series Solar inverter, some parameters is "manufacturers retain", the serial number in
the function parameter list is not listed, resulting in some of the parameters of the table number is
not connected, For the parameters not described in the manual, please do not try to modify to avoid
causing errors.
Code
Parameter name
Functional Description
d0
Monitoring function group
Monitoring frequency, current, etc
F0
Basic function group
Frequency setting, control mode.
F1
Input terminals group
Analog and digital input functions
F2
Output terminals group
Analog and digital output functions
F3
Start and stop control group
Start and stop control parameters
F4
V/F control parameters
V/F control parameters
F6
Keyboard and display
To set key and display function parameters
F7
Auxiliary function group
To set Jog, jump frequency and other auxiliary function
parameters
F8
Fault and protection
To set fault and protection parameters
F9
Communication parameter group
To set MODBUS communication function
Fb
Control optimization parameters
To set parameters of optimizing the control performance
E0
Solar pump special group
Solar pump special parameter setting
E2
PID function group
To set Built-in PID parameters
E3
Virtual DI, Virtual DO
Virtual I/O parameter setting
b0
Motor parameters
To set motor parameter
y0
Function code management
To set password, parameter initialization and parameter
group display
y1
Fault query
Fault message query
5-1-1.d0 Group - Monitoring function group
No.
Code
Parameter name
Setting range
Factory

Table of Contents

Related product manuals