Chapter 5 Function parameter
25
Detected value for DC bus voltage
Effective value for Actual motor current
Calculated value for motor output power
Motor actual running speed
Reference value percentage when PID runs
Feedback value percentage when PID runs
High-speed pulse
input frequency
High-speed pulse input frequency display, nit:
0.01Khz
Remaining run time display, it is for timing
run control
Total time of current inverter power-on
Total time of current inverter run
HDI(DI5) impulse
frequency
HDI(DI5) High-speed impulse input
frequency display, unit: 1Hz
Frequency, torque or other command values
set by communication port
Frequency set by F0.03 master frequency
setting source
Observe the set command torque under the
torque control mode
G type (constant torque load type)
AI1 voltage before
correction
Input voltage value before AI1 linear
correction
AI2 voltage before
correction
Input voltage value before AI2 linear
correction
AI3 voltage before
correction
Input voltage value before AI3 linear
correction
Motor temperature
inspection function3
PT100 inspect motor temperature value
5-1-2.F0 Group -Basic function group