Chapter 4 Installation and commissioning
15
Deflector
Cool wind
Hot wind
Figure 4-2 Heat insulation deflector up and down installation diagram
4-3.Wiring Diagram
Solar inverter wiring is divided by main circuit and control circuit. Users must properly
connect Solar inverter in accordance with the wiring connection diagram showing below.
4-3-1Function description of main circuit terminal
Connect to three-phase power supply, single-phase
connects to R, T; solar power connect to R, T
Braking resistor terminals
Connect to braking resistor
Connect to three-phase motor
Connect to DC reactor(remove the shorting block)
4-3-2Control circuit terminals arrangement
Output +10V power supply, maximum output current: 10mA
Generally it is used as power supply of external
potentiometer, potentiometer resistance range: 1kΩ to 5kΩ
Output +24V power supply, generally it is used as power
supply of digital input and output terminals and external
sensor.
Maximum output current: 200mA
When external signal is used to drive, please unplug PLC