Chapter 4 Installation and commissioning
16
jumpers , PLC must be connected to external power supply,
and to +24V (default).
1.Input range:(DC 0V to 10V/0 to 20mA), depends on the
selected AI1 jumper on control panel.
2.Input impedance: 20kΩ with voltage input, 500Ω with
current input.
1.Input range:(DC 0V to 10V/0to 20mA), depends on the
selected AI2 jumper on control panel.
2.Input impedance: 20kΩ with voltage input, 500Ω with
current input.
1, Input range:DC-10~+10V
2, Input voltage 20kΩ
Multi-function
digital input 1
1.Opto-coupler isolation, compatible with bipolar input,
Jump line PLC selection decisions;
2.Input impedance: 3.3kΩ;
3.Voltage range with level input: 19.2V to 28.8V;
Notes:DI5 input impedance 1.65kΩ.
Multi-function
digital input 2
Multi-function
digital input 3
Multi-function
digital input 4
Multi-function
digital input 5
Multi-function
digital input 6
Multi-function
digital input 7
Multi-function
digital input 8
High-speed
pulse input
terminals
Except the function of DI1 to DI4,DI6 to DI8,DI5 can also
be used as high-speed pulse input channels.Maximum input
frequency: 100kHz
The selected DA1 jumper on control panel determines
voltage or current output. Output voltage range: 0V to 10V ,
output current range: 0mA to 20mA
The selected DA2 jumper on control panel determines
voltage or current output. Output voltage range: 0V to 10V ,
output current range: 0mA to 20mA
Opto-coupler isolation, bipolar open collector output
Output voltage range: 0V to 24V , output current range:
0mA to 50mA
Subject to function code(F2.00)"SPB terminal output mode
selection"
As a high-speed pulse output, the highest frequency up to
100kHz;
Contactor drive capacity: normally closed contact 3A/AC
250V,normally open contact 5 A/AC 250V, COSø = 0.4.
Normally closed
terminals