Chapter 5 Function parameter
98
Stop at the selected mode
Motor overheating (Err.45) ( same as
F8.17 units digit)
Running time arrival(Err.26)( same as
F8.17 units digit)
Fault
protection
action
selection 3
User-defined fault 1(Err.27) ( same as
F8.17 units digit)
User-defined fault 2(Err.28) ( same as
F8.17 units digit)
Power-on time arrival (Err.29) ( same as
F8.17 units digit)
Deceleration up to 7% of the rated motor frequency,
and then continue running, automatically return to the
set frequency to run if the load drop does not happen.
PID feedback loss when running (Err.31)
( same as F8.17 units digit)
Fault
protection
action
selection 4
Too large speed deviation (Err.42) ( same as
F8.17 units digit)
Motor overspeed (Err.43) ( same as F8.17 units
digit)
Initial position error (Err.51) ( same as F8.17
units digit)
When "free stop" is selected, the inverter displays Err. *, and directly stops.When "Stop at the
selected mode" is selected, the inverter displays Arr. *, firstly stops at the selected mode and then
displays Err. * When "continue to run" is selected, the inverter continues to run and displays Arr. *,
the operating frequency is set by F8.24.
current frequency running
setting frequency running
Abnormal reserve frequency
running
Abnormal reserve frequency
When the inverter occurs faults during operation, and the troubleshooting mode for the fault
is set to "continue to run", the inverter displays Arr. *, and runs at the operating frequency set by
F8.24.
When "abnormal spare frequency" is selected, the value set by F8.25 is the percentage of the
maximum frequency.
Momentary power cut action selection