Chapter 5 Function parameter
107
Running
direction
Time(t)
... ...
E1.19
E1.00
E1.21
E1.01
E1.02
E1.14
E1.25
250ms Pulse
DO or RELAY output
E1.23
E1.20
E1.18
Diagram 5-31:Schematic diagram of simple PLC
Simple PLC power-down
memory selection
power-down memory selection
power-down without memory
PLC "Power-Down With Memory" means that the PLC operating stage and frequency before
power-down are memorized, and then it will continue to run from the position of the memorized
stage in next power-on. If Power-Down Without Memory is selected, the PLC process will restart
from the starting position for each power-on
PLC "Stop With Memory" means that the PLC operating stage and frequency before stop are
recorded, and then it will continue to run from the position of the recorded stage in next run. If
Stop Without Memory is selected, the PLC process will restart from the starting position for each
start.
0 stage ac/deceleration time selection
1 stage ac/deceleration time selection
2 stage ac/deceleration time selection
3 stage ac/deceleration time selection
4 stage ac/deceleration time selection
5 stage ac/deceleration time selection
6 stage ac/deceleration time selection