EasyManua.ls Logo

Powtran PI500 series - Page 57

Powtran PI500 series
166 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Chapter 5 Function parameter
53
Chapter 5
55kW)
449.
b0.10
Asynchronous motor
no-load current
0.01A to b0.03 (inverter power <=
55kW)
0.1A to b0.03 (inverter power>
55kW)
Motor
parameters
450.
b0.11
Synchronous motor
stator resistance
0.001Ω to 65.535Ω (inverter power
<= 55kW)
0.0001Ω to 6.5535Ω (inverter
power> 55kW)
-
451.
b0.12
Synchronous D-axis
inductance
0.01mH to 655.35mH (inverter power
<= 55kW)
0.001mH to 65.535mH (inverter
power> 55kW)
-
452.
b0.13
Synchronous Q-axis
inductance
0.01mH to 655.35mH (inverter power
<= 55kW)
0.001mH to 65.535mH (inverter
power> 55kW)
-
453.
b0.14
Synchronous motor
back-EMF
0.1V to 6553.5V
-
454.
b0.15 to
b0.26
Reserve
455.
b0.27
Motor parameter auto
tunning
0: no operation
1: asynchronous motor parameters
still auto tunning
2: asynchronous motor parameters
comprehensive auto tunning
11: synchronous motor parameters
still auto tunning
12: synchronous motor parameters
comprehensive auto tunning
0
456.
b0.28
Encoder type
0: ABZ incremental encoder
1: UVW incremental encoder
2: Rotational transformer
3: Sine and cosine encoder
4: Wire-saving UVW encoder
0
457.
b0.29
Encoder every turn
pulse number
1 to 65535
2500
458.
b0.30
Encoder installation
angle
0.00 to 359.90
0.00
459.
b0.31
ABZ incremental
encoder AB phase
sequence
0: forward 1: reverse
0
460.
b0.32
UVW encoder offset
angle
0.00 to 359.90
0
.
0
461.
b0.33
UVW encoder UVW
0: forward 1: reverse
0

Table of Contents