Chapter 5 Function parameter
69
Clear current running
time
If the terminal is valid, the inverter's current running time is
cleared, the function needs to work with Timing run (F7.42) and
current running time arrival(F7.45).
Jog running order,direction set through F7.54
Table 1 Multi command functions description
Over 4 segments command terminal, can be combined into 16 states, each state corresponds
to the 16 instruction set value. As shown in Table 1 below:
10-stage speed setting 10X
11-stage speed setting 11X
12-stage speed setting 12X
13-stage speed setting 13X
14-stage speed setting 14X
15-stage speed setting 15X
When multi-speed is selected as frequency source, the 100.0% of function code E1.00 to
E1.15 corresponds to maximum frequency F0.19. Multi-stage command is used for the function of
multi-speed, also for PID reference source to meet the need to switch between different reference
values.
Table 2 - function description of ac/deceleration time selection terminal.
Ac/deceleration time selection
This parameter defines four different modes to control inverter operation through external
terminals.0: Two-wire type 1
This mode is the most commonly used two-wire mode. The forward/reverse operation of
motor is determined by terminal DIx, DIy.
The terminal function is set as follows:
Of which, DIx and DIy are the multi-function input terminals of DI1 to DI10, the level is
active.