Chapter 5 Function parameter
25
0.Vector control W/O PG
2.V/F control
0.00Hz to F0.19 (Maximum
frequency)
Frequency command
resolution
Frequency source
master setting
0: Keyboard set frequency (F0.01,
UP/DOWN can be modified, power-
down without memory);
1: Keyboard set frequency (F0.01,
UP/DOWN can be modified, power-
down with memory);
2: Analog AI1 setting;
3: Analog AI2 setting;
4: Keypad potentiometer setting;
8: PID control setting;
9: Remote communications setting
Frequency source
auxiliary setting
Frequency source
auxiliary setting range
selection
0: Relative to maximum frequency
1: Relative to master frequency source 1
2:Relative to master frequency source 2
Frequency source
auxiliary setting range
Frequency source
superimposed
selection
Units digit:Frequency source selection
Tens digit: Arithmetic relationship of
master and auxiliary for frequency
source
Frequency source
offset frequency when
superimposing
0.00Hz to F0.19(Maximum frequency)
Shutdown memory
selection
0: W/O memory; 1: With memory
Frequency command
UP / DOWN
reference when
running
0: Running frequency;
1: Set frequency
0.Keyboard control (LED off)
1.Terminal block control (LED on)
2.Communications command control
(LED flashes)
3. Keyboard control+ Communications
command control
4. Keyboard control+ Communications
command control+ Terminal block
control