Chapter 5 Function parameter
30
Chapter 5
X2
5-1-4.F2 group - Output terminals group
No.
Code
Parameter name
Setting range
Factory
setting
Chan
ge
77
F2.01
Relay 1 output function selection
0 to 40
21
78
F2.02
Relay 2 output function selection
22
79
F2.03
Relay 3 output function selection
23
80
F2.04
Relay 4 output function selection
24
81
F2.05
Relay 5 output function selection
25
82
F2.06
Relay 6 output function selection
26
83
F2.07
Relay 7output function selection
27
84
F2.08
Relay 8 output function selection
28
Above5functioncodeisusedto selectfivedigital output function. Multifunctional output
terminalfunctionsareas follows:
Setting
value
Funtion
Description
0
No output
No outputaction
1
Inverter running
Inverter is in running state,the output frequency(Canbezero),the
output ON signal.
2
Faultoutput
(Faultdown)
Whenthedrive fails anddowntime,the outputON signal.
3
Frequencyleveldete
ction FDT1output
Pleaserefer to the functioncodeF7.23,F7.24's instructions.
4
Frequencyarrival
Pleaserefer to thedescriptionof functioncodeF7.25.
5
Zero-speedrunning
(No output
whenshutdown)
Inverter operationandthe output frequencyis0,outputON signal.
Whenthedriveis shutdown,thesignalis OFF.
6
Motor overloadpre-
alarm
Beforethemotor overloadprotection,according to the
overloadpre-alarm threshold value judgment,morethan the pre-
alarm thresholdvalue outputONsignal.Motor overload parameter
settings refer to the functioncodeF8.02~ F8.04.
7
Inverter
overloadpre-alarm
Beforetheinverter overloadoccurs10s,outputON signal.
8
Total
runningtimearrival
Inverter total runningtime of F6.07 morethan the setting time of
F7.21,output ON signal.
9
Limitedin
frequency
Whenthesetfrequencyexceeds the upper limitfrequencyor lower
frequency,andoutputfrequencyisbeyondthe upper
limitfrequencyor lower limitfrequency,outputON signal.
10
Readyto run
Whenthe inverter maincircuitandcontrolcircuitpower supplyhas
stabilized,andthedrivedoes notdetectanyfault
information,thedriveis inanoperationalstate,outputON signal.
11
AI1>AI2
Whenthe value of theanalog inputAIis greaterthanthe value
ofAI2inputandoutputON signal.
12
Upper frequency
arrival
Whenthe operating frequencyreaches the upper frequency,
outputON signal.
13
The lowerfrequency
arrival (No output
Whenthe operating frequencyreaches the lower frequency,
outputON signal.Thenextstopstatussignalis OFF.