Chapter 5 Function parameter
44
stop the pump frequency conversion, delay E8.10 time, after the time arrives, start the next
frequency conversion The pump works. If the time is up, there is a power frequency output to
restart the timing.
5-1-16.b0 group -Motor parameters
0: Normal asynchronous motor 1:
Asynchronous variable frequency motor
0.01A to 655.35A(Inverter power≤55kW)
0.1A to 6553.5A(Inverter power>55kW)
0.01Hz to F0.19(Maximum frequency)
Asynchronous
stator resistance
0.001Ω to 65.535Ω(Inverter power≤55kW)
0.0001Ω to 6.5535Ω(Inverter power >55kW)
Asynchronous
rotor resistance
0.001Ω to 65.535Ω(Inverter power≤55kW)
0.0001Ω to 6.5535Ω(Inverter power >55kW)
0.01mH to 655.35mH(Inverter power≤55kW)
0.001mH to 65.535mH(Inverter power>55kW)
Asynchronous
mutual
inductance
0.1mH to 6553.5mH(Inverter power≤55kW)
0.01mH to 655.35mH(Inverter power >55kW)
Asynchronous
no-load current
0.01A to b0.03(Inverter power≤55kW)
0.1A to b0.03(Inverter power >55kW)
Motor
parameter auto
tunning
0: no operation
11: synchronous motor parameters still auto
tunning
12: synchronous motor parameters
comprehensive auto tunning
5-1-17.y0 group -Function code management
0: No operation
1: Restore default parameter values, not
including motor parameters
2: Clear history
3: Restore default parameter values,
including motor parameters
4: Backup current user parameters
501: Restore from backup user
parameters
10: Clear keyboard storage area3
11:Upload parameter to keyboard storage