EasyManua.ls Logo

Powtran PI500-W Series - B0 Group -Motor Parameters; Y0 Group -Function Code Management

Powtran PI500-W Series
83 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Chapter 5 Function parameter
44
Chapter 5
stop the pump frequency conversion, delay E8.10 time, after the time arrives, start the next
frequency conversion The pump works. If the time is up, there is a power frequency output to
restart the timing.
5-1-16.b0 group -Motor parameters
No.
Code
Parameter
name
Setting range
Factory
setting
Chan
ge
321
b0.00
Motor type
selection
0: Normal asynchronous motor 1:
Asynchronous variable frequency motor
0
322
b0.01
Rated power
0.1 to 1000.0kW
Model
determination
323
b0.02
Rated voltage
1 to 2000V
Model
determination
324
b0.03
Rated current
0.01A to 655.35A(Inverter power≤55kW)
0.1A to 6553.5A(Inverter power>55kW)
Model
determination
325
b0.04
Rated frequency
0.01Hz to F0.19(Maximum frequency)
Model
determination
326
b0.05
Rated speed
1rpm to 36000rpm
Model
determination
327
b0.06
Asynchronous
stator resistance
0.001Ω to 65.535Ω(Inverter power≤55kW)
0.0001Ω to 6.5535Ω(Inverter power >55kW)
Motor
parameters
328
b0.07
Asynchronous
rotor resistance
0.001Ω to 65.535Ω(Inverter power≤55kW)
0.0001Ω to 6.5535Ω(Inverter power >55kW)
Motor
parameters
329
b0.08
Asynchronous
leakage
0.01mH to 655.35mH(Inverter power≤55kW)
0.001mH to 65.535mH(Inverter power>55kW)
Motor
parameters
330
b0.09
Asynchronous
mutual
inductance
0.1mH to 6553.5mH(Inverter power≤55kW)
0.01mH to 655.35mH(Inverter power >55kW)
Motor
parameters
331
b0.10
Asynchronous
no-load current
0.01A to b0.03(Inverter power≤55kW)
0.1A to b0.03(Inverter power >55kW)
Motor
parameters
332
b0.27
Motor
parameter auto
tunning
0: no operation
11: synchronous motor parameters still auto
tunning
12: synchronous motor parameters
comprehensive auto tunning
0
5-1-17.y0 group -Function code management
No.
Code
Parameter name
Setting range
Factory
setting
Chan
ge
333
y0.00
Parameter
initialization
0: No operation
1: Restore default parameter values, not
including motor parameters
2: Clear history
3: Restore default parameter values,
including motor parameters
4: Backup current user parameters
501: Restore from backup user
parameters
10: Clear keyboard storage area3
11:Upload parameter to keyboard storage
0

Table of Contents