Appendix I
74
67(Y group)low byte:00 to FF,this addres is written RAM
For example:
Function code F3.12 can not be stored into EEPROM, address indicates as 030C; function
code E3.05 can not be stored into EEPROM, address indicates as 4305; the address indicates that
only writing RAM can be done and reading can not be done, when reading, it is invalid address.
For all parameters, you can also use the command code 07H to achieve the function.
Stop/Run parameters section:
*Communication set value (-
10000 to 10000)( Decimal)
High-speed pulse input frequency,
unit:0.01kHz
Feedback speed, unit:0.1Hz
AI1 voltage before correction
AI2 voltage before correction
AI3 voltage before correction
High-speed pulse input frequency,
unit: 1Hz
Auxiliary frequency display
Note:
There is two ways to modify the settings frequencies through communication mode:
The first: Set F0.03 (main frequency source setting) as 0/1 (keyboard set frequency), and then
modify the settings frequency by modifying F0.01 (keyboard set frequency). Communication
mapping address of F0.01 is 0xF001 (Only need to change the RAM communication mapping
address to 0x0001).
The second :Set F0.03 (main frequency source setting) as 9 (Remote communication set), and
then modify the settings frequency by modifying (Communication settings). , mailing address of
this parameter is 0x1000.the communication set value is the percentage of the relative value, 10000
corresponds to 100.00%, -10000 corresponds to -100.00%. For frequency dimension data, it is the
percentage of the maximum frequency (F0.19); for torque dimension data, the percentage is F5.08
(torque upper limit digital setting).
Control command is input to the inverter: (write only)
0006: Deceleration and stop
Inverter read status: (read-only)