Section VI. Function Parameter Description
set frequency
H19
H14
H17
H16
H15
H14
H19
H18
>10ms
H08
H07
H09
H09
H08
H07
time
>10ms >10ms
>10ms
>10ms >10ms
time
time
timeoutput frequency
SS3
SS2
SS1
*7: Reserved
F64: Selection of input terminal’s polarity factory setting: 0
RST
FRE
SS3
SS2
REV
FWD
JOG
SS1
7 6 5 4 3 2 1 0
22222222
01234567
Set
Polarity of Input Terminal
Low level valid(close) Low level valid(close)
0
Falling edge valid, rising edge invalid Falling edge valid, rising edge invalid
High level valid(open) High level valid(open)
1
Rising edge valid, falling edge invalid
Rising edge valid, falling edge invalid
1 1 0 0 0 011
22222222
01234567
SS1
JOG
FWD
REV
SS2
SS3
FRE
RST
F64 =bit7*2
+bit6*2
+……+bit1*2
+bit0*2
=1*2
7
+1*2
6
+0*2
5
+0*2
4
+0*2
3
+0*2
2
+
1*2
1
+1*2
0
=128+64+2+1
Section VI. Function Parameter Description
F65: Monitor selection 2 factory setting: 1
Monitor the second objects, range from 0~15 (same as F00), valid when
using keyboards JP6E7000 and JP6C7000. Please refer to the keyboard
operation in the section III.
F66: Monitor selection 3 factory setting: 2
F65, F66 respectively select the first monitored object and the second
monitored object which range from 0~15(the same as F00 monitored
objects). They are valid when it is operated by JP6E7000 and JP6C7000.
Refer to the section III: Operating keyboard.
F67: V/F curve set
F68: MSS speed control
F69: I/O group select
F70: CUR group select
F71: SPD group select
F72: PID group select
F73: SYS group select
F74: MOT group select
Selecting one of these above groups as expected, press PRG running into
the relative group.
6-2. Other parameters
6-2-1. F67 V/F curve set [V/F]
U00: V/F set frequency 1 factory setting: 5.00/50.0Hz
User set the first frequency of V/F curve corresponding with V1.
U01: V/F set voltage 1 factory setting: 5%
User set the first voltage percentage of V/F curve corresponding with F1, by
the reference of inverter’s rated output voltage 100%.
U02: V/F set frequency 2 factory setting: 10.00/100.0Hz
User set the second frequency of V/F curve corresponding with V2.
U03: V/F set voltage 2 factory setting: 10%
User set the second voltage percentage of V/F curve corresponding with F2,
by the reference of inverter’s rated output voltage 100%.
U04: V/F set frequency 3 factory setting: 15.00/150.0Hz
User set the third frequency of V/F curve corresponding with V3.