Section VI. Function Parameter Description
H14: Acceleration time at1 factory setting: 10.0s
H15: Deceleration time dt1 factory setting: 10.0s
H16: Acceleration time at2 factory setting: 10.0s
H17: Deceleration time dt2 factory setting: 10.0s
H18: Acceleration time at3 factory setting: 10.0s
H19: Deceleration time dt3 factory setting: 10.0s
H20: Acceleration time at4 factory setting: 10.0s
H21: Deceleration time dt4 factory setting: 10.0s
H22: Acceleration time at5 factory setting: 10.0s
H23: Deceleration time dt5 factory setting: 10.0s
H24: Acceleration time at6 factory setting: 10.0s
H25: Deceleration time dt6 factory setting: 10.0s
H26: Acceleration time at7 factory setting: 10.0s
H27: Deceleration time dt7 factory setting: 10.0s
Set the Acc/Dec time of 7 steps respectively. They determine the
time needed to reach the speed, respectively depending on the
acceleration time for acceleration or on the deceleration time for
deceleration, but the time is not the actual time needed. Actual
acc/dec time equals to the set acc/dec time multiples a time multiple
which is decided by the tens digit of F56. Please refer to F56.
Definite acceleration and deceleration time for multi-step speed.
T3T2T1
dt3dt2
at2
at1
3X
2X
1X
output
frequency
time
Definition of multi-step speed acceleration/deceleration time
at1: Step 1 acceleration time at2: Step 2 acceleration time
dt2: Step 2 deceleration time dt3: Step 3 deceleration time
H28: Multi-step speed 1 running direction factory setting: 0
H29: Multi-step speed 2 running direction factory setting: 0
H30: Multi-step speed 3 running direction factory setting: 0
H31: Multi-step speed 4 running direction factory setting: 0
H32: Multi-step speed 5 running direction factory setting: 0
Section VI. Function Parameter Description
H33: Multi-step speed 6 running direction factory setting: 0
H34: Multi-step speed 7 running direction factory setting: 0
In program multi-speed l running, these parameters decide the direction of
each speed.
The running direction
Setting value
forward 0
backward 1
In terminal multi-speed running:
When running control mode F050/1/2, these parameters decide the
direction of each speed.
When running control mode F05 3, these parameters and terminal
FWD/REV decide the direction of each speed together.
FWD=1
running direction
FWD=1
running direction
Setting value
forward backward 0
backward forward 1
6-2-3. F69 Input/output parameter [I/O]
o00: filter time of V2 signal input factory setting: 10ms
It may be 2~200ms. If the time is too long, setting frequency change is
steady, but response speed will become bad; if the time is too short, setting
frequency stability become badly, but response speed will be rapider.
o01: V2 minimum input voltage factory setting: 0.00V
The minimum input voltage of input terminal V2, may be any value between
0~V2 maximum input voltage.
o02: V2 maximum input voltage factory setting: 10.00V
The maximum input voltage of input terminal V2, may be any value between
V2 minimum input voltage to 10V.
o03: I input filter time factory setting: 10ms
It may be 2~200ms. If the time is too long, setting frequency change is
steady, but response speed will become bad; if the time is too short, setting
frequency stability become badly, but response speed will be rapider.
o04: I input minimum current factory setting: 0.00mA
The minimum input current of input terminal I2, may be any value between
0~I2 maximum current.
o05: I input maximum current factory setting: 20.0mA
The maximum input current of input terminal I2, may be any value between
I2 minimum current to 20.00 mA.
e.g. V2 input 1~5V, o01=1V, o02=5V; I2 input 4-20mA, o04=4mA,