EasyManua.ls Logo

Powtran PI7500 Series - F25: DC braking time when stopping; F26: Braking start up frequency; F27: Stop mode set; F28: Jog acceleration time

Powtran PI7500 Series
41 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Section VIII. Standard Specifications
Multi-segment
acceleration
At most 8 steps acceleration can be set (using multi function terminals or
program running.)
instant stop Interrupt controller's output.
traverse running Program control running
jog running in low speed
fault reset
When the protection function is affective, system can reset fault state
automatically.
PID feedback signal
DC 0~10V, DC 1~5V, DC 0~20mA, DC 4~20mA
running state
motor state display, stop, accelerate/decelerate, seven-speed,
program running state
fault output relay fault output: AC125V 3A, DC 30V 3A
analog output
1 analog output, 8 signals could be selected: frequency, current, voltage,
temperature, etc, the output signal range is 0~10V/0~20mA.
Output signal
output signal 6 output signals, each one with 20 signals for option.
running function
Limit frequency, skip frequency, torque difference compensate, reverse
protection, automatic adjustment
running
DC brake
On base of non-OC, internal PID can regulate braking current to ensure
enough braking torque.
inverter protection
Over voltage, under voltage, over current, over load, overheat, over current
stall, over voltage stall, external fault.
IGBT temperature
display
Display of current IGBT temperature
inverter fan control Temperature of starting the fan can be set.
restart after momentary
power loss
less than 15ms:continue running
More than 15ms:automatic inspection of motor's speed, restart after
transient power down.
speed starting pursue
mode
inverter pursue motor speed automatically before starting
Protection function
parameter protection
function
protect inverter's parameter by setting password and decode
running
message
set frequency, actual frequency, actual current, actual current percentage,
DC bus voltage, actual output voltage, actual motor's speed, total running
time, IGBT temperature, motor output power percentage. Display of
3parameters simultaneity at most: F00,F65 and F66.
display
LCD
English
Display
+
LED
keyboard
fault
message
Store 5 fault messages at most, and can inquire about fault style, voltage,
current, frequency and the work state at the same time
environment
temperature
-10 ~ 40
storage temperature -20 ~65
environment humidity Less than 90 % RH
Height / libration less than 1,000 m, less than 5.9m/s
2
(=0.6g)
environment
application place where there is no rust gas, no flammability gas, no grease and dust
cooling methods Forced air cooling and natural cooling
Section VIII. Standard Specifications
8-3 Sharp Size
High voltage inside.
Perform parts replacement after discharge
is finished.
Confirm the output or control wires are not
grounded.
Refer to the operation manual when adjust
or inspect.
CAUTION
ALARMFWD VA
HZ
% S
REV
DIGITAL OPERATOR
JP-10
RUN
STOP
RESET
PRG
SET
ESC
DISPL
8-4 External Keyboard size
JP6E7000/ JP6C7000
ALARM
SPEED-STATUS
REV
SET
PRG
DIGITAL OPERATOR
FWD
ESC
DISPL
JOG
REV
FWD
STOP
RESET
JP-07
Fixed on the panelholes dimension(131±0.1)×(70.8±0.1)