Section VII Standard Specifications
105
Motor status display, stop, acceleration and deceleration,
constant speed, the program running.
Built-in PID regulator brake current flow in the premise,
however, to ensure adequate braking torque.
Overvoltage protection, undervoltage protection, over-
current protection , overload protection,over-temperature
protection, over the loss of speed protection, over-voltage
stall protection , phase protection (optional) , external
fault , communication error , PID feedback signal
abnormalities , PG failure
Display current IGBT temperature
The fan starting temperature can be set(optional)
Instant power-down re-start
Less than 15 milliseconds: continuous operation.
Greater than 15 milliseconds: Automatic detection of
motor speed, instantaneous power-down re-start.
Speed starting track method
automatically track motor speed when inverter starts
Parameter protection
function
Protect inverter parameters by setting the password and
decoding
Can be customized into 68 kinds of functions, to achieve
forward, reverse, forward jog, and reverse jog, emergency
stop, reset, speed, acceleration speed, run-time switch, and
pulse counting.
Can be defined as a switch input;
To allow for maximum input range-10V ~ +10V, 0 ~
20mA
Can achieve output range 0 ~ +10V, 0 ~ 20mA
Virtual terminal function
Can be set to a virtual terminal, using communication or
keyboard IO port, and with the IO port status display.
In 6 main ways + to 7 kinds of auxiliary to the way of the
keyboard, three way analog input, pulse input, digital
potentiometers.
8-core cable,in line with EIA T568A,EIA T568B standards.
Supports dual-keyboard,synchronous control,independently
of each other.
Double and multi function
keys
MF1, MF2 can be customized as addition and subtraction,
forward, reverse, forward jog, and reverse jog, emergency
stop, rise and fall, and other 9 kinds of ways.
Control panel can be realized four groups of inverter
parameters of upload, download, with manufacturer
password to reset factory setting.
At most display 3 monitoring parameters. Select by A00,
A01, A02